HUAYI INVERTER COMPRESSOR R600a MODELS
Model | Power supply (V/rpm) |
Displacement (cm3) |
Cooling Capacity(W) |
COP (W/W) |
Motor Type |
VK52CL | 220~240/1200 | 5.2 | 34 | 1.55 | BLDC |
220~240/1800 | 54 | 1.60 | |||
220~240/2400 | 74 | 1.65 | |||
220~240/3000 | 90 | 1.60 | |||
220~240/4500 | 125 | 1.60 | |||
VK70CL | 220~240/1200 | 7.0 | 47 | 1.60 | BLDC |
220~240/1800 | 74 | 1.75 | |||
220~240/2400 | 100 | 1.80 | |||
220~240/3000 | 123 | 1.75 | |||
220~240/4500 | 175 | 1.60 | |||
VK90CL | 220~240/1200 | 9.0 | 64 | 1.60 | BLDC |
220~240/1800 | 97 | 1.75 | |||
220~240/2400 | 130 | 1.80 | |||
220~240/3000 | 158 | 1.75 | |||
220~240/4500 | 215 | 1.60 | |||
VM45CL* | 220~240/1200 | 4.5 | 28 | 1.55 | PMSM |
220~240/1800 | 45 | 1.65 | |||
220~240/2400 | 56 | 1.65 | |||
220~240/3000 | 70 | 1.65 | |||
220~240/4500 | 105 | 1.60 | |||
VM70CL* | 220~240/1200 | 7.0 | 45 | 1.70 | PMSM |
220~240/1800 | 72 | 1.75 | |||
220~240/2400 | 98 | 1.75 | |||
220~240/3000 | 129 | 1.75 | |||
220~240/4500 | 170 | 1.65 | |||
VM90CL* | 220~240/1200 | 9.0 | 64 | 1.50 | PMSM |
220~240/1800 | 98 | 1.70 | |||
220~240/2400 | 131 | 1.70 | |||
220~240/3000 | 168 | 1.65 | |||
220~240/4500 | 220 | 1.55 | |||
VM110CL* | 220~240/1200 | 11.0 | 78 | 1.50 | PMSM |
220~240/1800 | 118 | 1.70 | |||
220~240/2400 | 155 | 1.70 | |||
220~240/3000 | 192 | 1.65 | |||
220~240/4500 | 270 | 1.55 |
Test conditions | According to ASHRAE |
Evaporating temperature | -23.3℃ |
Condensing temperature | 54.4℃ |
Subcooling temperature | 32.2℃ |
Suction temperature | 32.2℃ |
Ambient temperature | 32.2℃ |
Working condition limit:R600a
Max ambient temperature | 43[℃] |
Evaporation temperature | -35~-15[℃] |
Working voltage range | 170~270[V] |
Max discharge pressure | 0.98[Mpa] (gauge pressure) |
Max allowable housing temperature | 95[℃] |
Max discharge temperature | 130[℃] |
Max pressure housing endured | 3.5 [Mpa] (gauge pressure) |
Low voltage start | 0.3/0.3Mpa (gauge pressure) 160V |